Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(6)2023 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-37374330

RESUMO

Background and Objectives: Sutureless aortic valve prostheses have presented favorable hemodynamic performance while facilitating minimally invasive access approaches. As the population ages, the number of patients at risk for aortic valve reoperation constantly increases. The aim of the present study is to present our single-center experience in sutureless aortic valve replacement (SU-AVR) in reoperations. Materials and Methods: The data of 18 consecutive patients who underwent SU-AVR in a reoperation between May 2020 and January 2023 were retrospectively analyzed. Results: The mean age of the patients was 67.9 ± 11.1 years; patients showed a moderate-risk profile with a median logistic EuroSCORE II of 7.8 (IQR of 3.8-32.0) %. The implantation of the Perceval S prosthesis was technically successful in all patients. The mean cardiopulmonary bypass time was 103.3 ± 50.0 min, and the cross-clamp time was 69.1 ± 38.8 min. No patients required a permanent pacemaker implantation. The postoperative gradient was 7.3 ± 2.4 mmHg, and no cases of paravalvular leakage were observed. There was one case of intraprocedural death, while the thirty-day mortality was 11%. Conclusions: Sutureless bioprosthetic valves tend to simplify the surgical procedure of a redo AVR. By maximizing the effective orifice area, sutureless valves may present an important advantage, being a safe and effective alternative not only to traditional surgical prostheses but also to transcatheter valve-in-valve approaches in select cases.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese
2.
J Clin Med ; 12(12)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37373856

RESUMO

INTRODUCTION: Due to their favourable hemodynamic performance and the ability to enable minimally invasive access procedures, sutureless aortic valve prostheses have found their place in the armamentarium of cardiothoracic surgeons. In this study, we sought to review our institutional experience of sutureless aortic valve replacement (SU-AVR). METHODS: We carried out a retrospective analysis of 200 consecutive patients who underwent an SU-AVR with a Perceval valve between December 2019 and February 2023. RESULTS: The mean age of patients was 69.3 ± 8.1 years, and patients showed a moderate-risk profile with a mean logistic EuroSCORE-II of 5.2 ± 8.1%. An isolated SU-AVR was performed in 85 (42.5%) patients, concomitant CABG was performed in 75 (37.5%) and 40 patients (20%) underwent a multivalve procedure involving SU-AVR. The cardiopulmonary bypass (CPB) and cross-clamp (CC) times were 82.1 ± 35.1 and 55.5 ± 27.8 min, respectively. In-hospital, 30-day, 6-month and 1-year mortality rates were 4.5%, 6.5%, 7.5% and 8.2%, respectively. The postoperative transvalvular mean pressure gradient was 6.3 ± 1.6 mmHg and stayed stable over the follow-up time. We reported no cases of paravalvular leakage, and the incidence of stroke was 0.5%. CONCLUSIONS: With their favourable hemodynamic performance and shorter CC and CPB times, sutureless aortic valve prostheses facilitate minimally invasive access surgery, being a safe and durable promising approach for the surgical AVR.

3.
Life (Basel) ; 13(3)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36983892

RESUMO

BACKGROUND: Sutureless aortic valve prostheses have proven to provide a significant decrease in procedural, cardiopulmonary bypass and cross-clamp time, leading to a significant reduction in mortality risk in elderly high-risk cohorts. In this study, we sought to review our institutional experience on the sutureless aortic valve replacement (SU-AVR) and the concomitant mitral valve replacement (SMVR), comparing the combined conventional surgical aortic valve replacement (SAVR) with SMVR. METHODS AND MATERIAL: Between March 2018 and July 2022, 114 consecutive patients underwent a combined aortic and mitral valve replacement at our institution. We stratified the patients according to the operative procedures into two groups and matched them 1:2: Group 1 underwent a combined conventional SAVR and SMVR (n = 46), and Group 2 included combined SU-AVR with Perceval prosthesis and SMVR (n = 23). RESULTS: No significant differences in the preoperative characteristics were present. SU-AVR combined with SMVR demonstrated excellent haemodynamic performance, comparable to that of SAVR plus SMVR, with median postoperative gradients over the aortic valve of 4 mmHg (IQR 3.0-4.0) in Group 1 and 4 mmHg (IQR 3.0-4.0) in Group 2 (p = 0.67). There was no significant difference in the occurrence of postoperative major adverse events such as death, stroke, myocardial infarction and kidney failure between the groups. There was also no significant difference in the permanent pacemaker implantation rate, paravalvular leakage or valve dislocation. We also could not detect any significant difference in postoperative mortality between the groups. CONCLUSIONS: SU-AVR has proven to be a reliable alternative to conventional valve prostheses in patients with multivalve disease undergoing combined aortic and mitral valve replacement, offering shorter procedural time and outstanding hemodynamic performance compared to the conventional surgical method.

4.
Artif Organs ; 47(3): 481-489, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36219511

RESUMO

BACKGROUND: Bioengineered transplantable heart-lung scaffolds could be potentially lifesaving in a large number of congenital and acquired cardiothoracic disorders including terminal heart-lung disease. METHODS: We decellularized heart-lung organ-blocks from rats (n = 10) by coronary and tracheal perfusion with ionic detergents in a modified Langendorff circuit. RESULTS: In the present project, we were able to achieve complete decellularization of the heart-lung organ-block. Decellularized heart-lung organ-blocks lacked intracellular components but maintained structure of the cellular walls with collagen and elastic fibers. CONCLUSIONS: We present a novel model of combined perfusion and decellularization of heart-lung organ-blocks. This model is the first step on the pathway to creating bioengineered transplantable heart-lung scaffolds. We believe that further development of this technology could provide a life-saving conduit, significantly reducing the risks of heart-lung failure surgery and improving postoperative quality of life.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Ratos , Animais , Alicerces Teciduais/química , Qualidade de Vida , Matriz Extracelular/química , Pulmão , Perfusão
5.
J Cardiothorac Surg ; 17(1): 198, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-35996140

RESUMO

BACKGROUND: In the era of transcatheter methods, patients presenting with a pure aortic regurgitation (AR) are not considered eligible for transcatheter treatment and therefore require another less invasive surgical option. We sought to review our experience with sutureless aortic valve replacement (SU-AVR) in patients presenting with symptomatic pure AR, which until now is a contraindication for implementation of sutureless valve prostheses in Europe. METHODS: Between April 2018 and June 2021, 80 consecutive patients underwent a SU-AVR for various indications at our institution. We analyzed the outcomes and postoperative complications of 12 patients presenting with a pure severe AR undergoing SU-AVR using Perceval (Corcym). RESULTS: The mean age of the patients was 67 ± 9.1 years old. All patients presented with symptomatic pure AR. Patients presented with multiple comorbidities as reflected by the mean EuroSCORE-II of 3.6 ± 2.6%. Six patients (50%) underwent a concomitant CABG procedure. The mean operating- and cross clamp time was 127.25 ± 45.9 and 40.33 ± 17.3 min respectively. All isolated SU-AVR were performed via J-sternotomy or right anterolateral thoracotomy. There were no cases of device dislocation. No patients presented with a paravalvular leakage. We observed excellent mean postoperative pressure gradient at follow-up 5.7 ± 1.5 mmHg. CONCLUSIONS: Our experience with SU-AVR shows the feasibility of sutureless technologies in the aortic valve surgery due to pure AR. Besides the great technical success and excellent hemodynamics, SU-AVR in severe AR offers a great opportunity of reducing the invasivity of the surgical procedure and potentially reducing hospital cost without compromising the postoperative outcomes and in-hospital length of stay.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento
6.
Life (Basel) ; 12(7)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35888069

RESUMO

BACKGROUND: The rapid development of transcatheter treatment methods has made transcatheter aortic valve replacement (TAVR) a feasible alternative to conventional surgical aortic valve replacement (SAVR). Recently, indications for TAVR have been expanded to intermediate- and low-risk patients, although there still remains a portion of ineligible patients. We sought to evaluate and compare our experience with sutureless SAVR and transapical TAVR in the "grey-area" of patients unsuitable for transfemoral access. METHODS: Between April 2018 and June 2021, 248 consecutive patients underwent a sutureless SAVR (SU-SAVR) or TA-TAVR at our institution. We performed a pair-matched analysis and identified 56 patient pairs based on the EuroSCORE II. All transcatheter procedures were performed using SAPIEN XT/3™ prostheses, while all surgical procedures deployed the Perceval (LivaNova) aortic valve. RESULTS: All patients presented with multiple comorbidities as reflected by the median EuroSCORE-II of 3.1% (IQR 1.9-5.3). Thirty-four patients from the surgical group (60.7%) underwent a concomitant myocardial revascularization. There was no significant difference in major adverse events, pacemaker implantation or postoperative mortality during follow-up. Both interventions demonstrated technical success with similar mean postoperative pressure gradients at follow-up and no cases of paravalvular leakage. CONCLUSIONS: Sutureless aortic valve replacement constitutes a feasible treatment alternative for patients with aortic valve disease who are ineligible for transfemoral access route and/or require concomitant coronary revascularization. With its excellent hemodynamic performance, similar survival compared to TA-TAVR, and high cost-efficiency without compromising the postoperative outcomes and in-hospital length of stay SU-AVR might be considered for patients in the "grey-area" between TAVR and SAVR.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...